Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.
About the layout of the air-conditioning room for the decoration of the purification project
In order to ensure that the line of the air duct is short, the air conditioner room should be close to the purification engineering workshop with high demand for air supply. However, in order to avoid noise and vibration, the air-conditioning room should be separated from the car. Therefore, it is necessary to do a good job in the layout of the air-conditioning room during the decoration.
First, the structure of separation
The structure separation type is mainly divided into 3 types, namely: the settlement joint separation type, the sandwich wall separation type, and the auxiliary chamber separation type.
1. Settlement joint separation type: In this way, the settlement joint can be passed between the pharmaceutical cleanroom and the machine room, thus playing a role of separation.
2. Partitioned by wall: In this way, the air-conditioning room can be close to the workshop, but there is no common partition between the two, but each has its own partition. There are gaps of corresponding width between the walls.
3. Auxiliary room partition type: In this way, there can be an auxiliary room between the air conditioning machine room and the purification engineering workshop, so as to play a buffering role.
Second, decentralized
Decentralized is mainly divided into two types, namely: top-level decentralized and underground decentralized.
1. Top surface distributed type: common in multi-storey buildings, the air-conditioning room is installed on the top floor of the building, keeping it away from the pharmaceutical cleanroom on the lower floor, so as to avoid noise and vibration. Note, however, that it is recommended that the next level on the top floor be used as an auxiliary or management room level.
2. Underground distributed type: common in single-storey buildings, the air-conditioning room is installed in the basement to avoid noise and vibration.
Three, individual building type
When the purification project is decorated, a separate building can be installed near the workshop and used as an air-conditioning room, but sound insulation and vibration isolation must be done well.
1. Sound insulation: mufflers should be installed on the related equipment of the air-conditioning room, materials with sound absorption properties should be attached to the wall, and sound insulation doors should be installed.
2. Vibration isolation: Anti-vibration treatment should be done at the brackets and bases of fans, motors and pumps. If desired, the equipment can be mounted on a concrete slab and the slab supported with anti-vibration material.
PHARMA saves time and increases productivity because it's one of the most complete sources of business and contact information.
If you follow these straightforward steps you can keep your extraction machine extraction machine. I think this article will help you make a wise decision on choosing the right .
There have been conclusive evidence on 's role in extraction machine and extraction machine.