Other faults of high-speed tablet press
1. The timing belt is too tight or too loose, just adjust it appropriately;
2. The phase resonance between the motor and the mechanical transmission part should avoid the speed of the vibration section;
3. Long-term use causes large gaps in the transmission part and loose parts. Adjust the gap and tighten the parts;
4. There are many particles and sticky, causing blockage, adjust the particles to solve;
5. Shafts and bearings are worn due to lack of oil and should be checked and replaced regularly;
6. The main worm gear box is short of oil, wears out, and generates noise, so the lubricating oil should be replaced regularly;
7. The pressure on both sides of the high-speed tablet press is unbalanced, and the adjustment is consistent.
The above content involves many factors, including factors of use and factors of improper adjustment. During the use of the tablet press, the tablet press chamber should be cleaned regularly, and the working parts that are easy to wear should be regularly inspected and maintained.