loading

Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.

GMP workshop liquid dispensing system

GMP workshop liquid dispensing system

The basic structure of the liquid dispensing system in the GMP pharmaceutical cleanroom consists of a filling body, a stirring system, a ventilation system, a temperature control system, a feeding system, a sampling system and an automatic control system; Specialized cleaning equipment CIP station to provide response to biological...

Text label: GMP clean workshop, GMP pharmaceutical cleanroom system

GMP plant dosing system

The basic structure of the liquid dispensing system in the GMP pharmaceutical cleanroom consists of a filling body, a stirring system, a ventilation system, a temperature control system, a feeding system, a sampling system and an automatic control system; The special cleaning equipment CIP station is used to provide cleaning liquid and cleaning power for cleaning the bioreactor. The objects to be cleaned include the filling body, feeding pipeline, ventilation pipeline, sampling pipeline, and liquid outlet pipeline of the bioreactor. Cleaning process: Purified water rinsing → normal temperature clean compressed air purging → lye cleaning → normal temperature clean compressed air purging → purified water rinsing → normal temperature clean compressed air purging → injection water rinsing → normal temperature clean compressed air purging → cleaning qualification inspection .

Aseptic liquid dispensing system has automatic sterilization function, including empty tank sterilization and solid tank sterilization, sterilization includes filling body, feeding pipeline, ventilation pipeline, sampling pipeline, liquid outlet pipeline, tube Road sterilization can be carried out at the same time as the sterilization of the filling body, or it can be carried out separately; the sterilization requirement is to maintain the sterilization temperature at 121 °C for 30 minutes. The liquid system has the sterilization of the filling body and the liquid outlet pipeline, which can be sterilized regularly or without sterilization function. The liquid distribution system has the function of pressure balance, including the intake pipeline and the exhaust pipeline. The clean compressed air is introduced into the tank for pressure maintenance and pressure liquid transportation. It is discharged out of the tank to avoid polluting the environment; the inlet and exhaust filters of the liquid dispensing system should use the same filter. The sterile liquid dispensing system is equipped with a sterile liquid inlet pipeline for aseptic concentrated solution, the addition of pH-adjusted acid and alkali materials, and a sterile water liquid inlet pipeline. The solid materials of the non-sterile liquid dispensing system pass through the manhole or feed materials The hole is manually added, the water is automatically added through the hard pipe or the hose is manually connected, and the pH-adjusted acid and alkali materials are manually added through the spare port. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for GMP workshops and GMP workshops.

Materials that are difficult to dissolve at low temperature need to increase the dosing temperature to improve the dosing efficiency, which is usually realized by introducing industrial steam into the jacket; many dosing tanks will not be used immediately after dosing or can be used once. The liquid needs to be stored in the tank for a period of time. In order to reduce the microbial load, the temperature in the tank needs to be controlled at 2-8℃. The liquid dosing system is equipped with a pressure sensor, which is associated with the intake and exhaust control valves to automatically control the tank pressure, with a liquid sensor or load cell, and is associated with the inlet and outlet valves to automatically control the volume or quality of the liquid in the tank; for aseptic dosing systems , The side wall of the tank should be designed with sampling function. The sampling pipeline can be sterilized separately before each sampling to realize aseptic sampling. For non-sterile liquid dispensing system, the side wall of the tank should be designed with sampling function, and single-channel sampling is adopted. Valve or ordinary diaphragm valve for sampling; the liquid from the dispensing system can be transported to the object of use by a centrifugal pump or hydraulically transported to the object of use through the dispensing tank. According to the sterility requirements of the object of use, it can be selected whether the liquid outlet pipeline is sterilized or not. And increase the sterilization filter device.

extraction machine CUSTOM SOLUTION SERVICES processes have been widely used to produce extraction machine such as extraction machine, extraction machine, and extraction machine etc.

Visit SUZHOU PHARMA MACHINERY CO.,LTD. in China for professional CUSTOM SOLUTION SERVICES tips and qulity ensured . The company is a licensed, bonded, and insured provider with decades of experience. Make your enquiry, today.

The major classifications of are extraction machine, extraction machine, extraction machine and extraction machine machines.

These extraction machine CUSTOM SOLUTION SERVICES have made the life easier. The best feature of the is its extraction machine.

GET IN TOUCH WITH Us
recommended articles
Project
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect