Focuses On Professional Cleanroom Project And Pharmaceutical Cleanroom Equipment.
After the production is over, first use a brush to clean the remaining powder, and then disassemble the detachable parts such as the feeder, powder scraper, hopper, and vacuum cleaner (disassembled from top to bottom) and move them to the tool cleaning room; the feeder, scraper, etc. Rinse the duster, vacuum cleaner, dust bag, etc. with drinking water for 3 times, clean the parts that are not easy to scrub with a small brush, and add an appropriate amount of 100ml of detergent if necessary. After cleaning, dry the surface with a clean rag, take 1000ml of disinfectant, and use a clean rag dipped in the disinfectant to wipe the feeder, powder scraper, and feeder