Microbiology pharma machinery design layout and installation
The microbiology pharma machinery should be set up in an independent area, separated from other laboratories, with access control at the entrance, non-workers are not allowed to enter, each room should be reasonably arranged according to the work content, not only work in one area without affecting each other, and set up a centralized type at the entrance Dressing room, culture room According to the culture strip...
Text label: Microbiology laboratory design layout, laboratory installation layout
Microbiology laboratory design layout and installation
The microbiology laboratory should be set up in an independent area, separated from other laboratories, with access control at the entrance, non-workers are not allowed to enter, each room is reasonably arranged according to the work content, which is convenient for work without affecting each other, and a centralized type is set at the entrance. Dressing rooms and cultivation rooms can be set up according to different cultivation conditions and types, such as fungal cultivation, bacterial cultivation, etc.; the clean laboratory forms its own area, which is arranged in the corner of the laboratory, and the rooms with clean requirements are set in the personnel In places with less interference, set the auxiliary room outside, consider the microbiological experiment operation process, and place the identification room adjacent to the cultivation room and the cleaning room to facilitate the separation of personnel and logistics; the clean laboratory requires staff to enter the corridor and then enter the preparation area. And enter the dressing room from the preparation area and the buffer area into the operation area; the air outlet is equipped with a high-efficiency filter, the air supply port is equipped with a high-efficiency filter static pressure box, the indoor air supply and exhaust adopts the upper and lower row methods, and the indoor air exhaust is unilateral. There should be no obstacles in the layout; the residual pressure valve automatically adjusts the indoor pressure to keep the positive pressure clean.
In the culture room, the staff enters the preparation area from the corridor, and directly enters the culture room from the preparation area, mainly equipped with various incubators; the size of the disinfection room is determined according to the daily workload, the water supply and drainage facilities are complete, and the ground should have good Drainage slope and floor drain. The walls of the microbiology laboratory, including the ceiling, should have a solid structure, good air tightness, and all inner corners should be transitioned with arc-shaped lines. The interior of the wall should be smooth, non-adsorbing, corrosion-resistant, and easy to clean and disinfect; the floor material should meet the requirements of no gaps. , no leakage, clean, corrosion-resistant requirements; the lamps and lanterns use purification lamps, which can achieve the characteristics of easy cleaning and no dust accumulation; the cabinets and test benches in the test bench should be firm, and the test bench, cabinet and other equipment should be kept between them. The test table should be waterproof, corrosion-resistant and heat-resistant, and epoxy resin table top is generally used; the laboratory door should be a clean door, with a visual window and an automatic door closer, and reach an appropriate fire rating, and the door should be The door cannot be opened facing directly, it must be opened diagonally; there is a reliable power supply and emergency lighting, and each room must be equipped with ultraviolet germicidal lamps, and the installation height of the germicidal lamps is between 1.8-2.1m; the design and construction of the equipment And installation should be easy to operate, easy to maintain, clean and eliminate contamination. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for microbiological laboratories and clean laboratories.
Common equipment in microbiology laboratory: incubator, microscope, biological safety cabinet, automatic bacterial identification and analysis system, etc.; auxiliary equipment includes drying oven, sterilizer, balance, spectrophotometer, acidity meter, refrigerator, constant temperature water temperature bath Pots, centrifuges, microscopic image analysis systems, sample dispensers, computers; the placement of laboratory instruments should follow the principles of safety, efficiency, reasonable procedures, and convenient work.
Looking for an innovative range of extraction machine CUSTOM SOLUTION SERVICES products? SUZHOU PHARMA MACHINERY CO.,LTD. supplies a diverse range of consumer, commercial and specialty industrial products including CUSTOM SOLUTION SERVICES, extraction machine, extraction machine,etc.Click PHARMA MACHINERY to learn more!