Even if the staff in the purification plant can be clean and hygienic, because the human body is an organic entity with living activities, it will always emit polluted particles to the surrounding environment. In order to minimize the pollution caused by human activities, the personnel Before entering the clean area, clean clothes must be changed...

Text label: purification plant decoration, purification plant engineering company, personnel purification measures

Purification measures for personnel in the purification plant

Even if the staff in the purification plant can be clean and hygienic, because the human body is an organic entity with living activities, it will always emit polluted particles to the surrounding environment. In order to minimize the pollution caused by human activities, the personnel Before entering the clean area, you must change clean clothes, and some also need to shower, disinfect or blow air; personnel purification is mainly to prevent the contamination brought in by staff from non-clean areas or low cleanliness areas, specifically, personnel purification The layout includes two parts: living room and personnel purification room; living room includes utility room, toilet, shower room, rest room; purification room mainly includes rain gear storage room, shoe changing room, coat storage room, toilet, changing room It consists of clean work clothes room, air lock room or shower room, etc. The living room is generally arranged before the purification room; some clean areas require strict separation, and the personnel purification room and the living room should be arranged on the same floor, but try not to Interspersed; in line with the principles of convenience and gradual improvement of cleanliness, some rooms that workers have the least contact with after entering the factory are usually arranged in the outermost layer, such as coat storage, rain gear storage, etc.

Different cleanliness levels have different requirements for changing clothes, but basically the selection of materials, styles and wearing methods of work clothes are required to be compatible with the production operation and air cleanliness level requirements, and should not be mixed. The texture of clean work clothes should be smooth and not Generates static electricity, does not shed fibers and particulate matter; if it is sterile work clothes, it must cover all hair, beards and feet, and can block human body shedding and prevent pollution caused by microorganisms on the hair and dust on the hair. In order to ensure that the clean clothes meet the hygienic requirements, the clean clothes should be cleaned and arranged regularly. The work clothes used in different air cleanliness levels should be cleaned and arranged separately, and generally cleaned in a clean area with a higher degree of cleanliness than the one used, and disinfected and sterilized if necessary. ; Additional particulate matter should not be brought into the clean room during washing and sterilization. The changing rooms at different production stages should be separated, and the work clothes worn by operators in the operation areas of different cleanliness levels should be clearly marked in terms of color and material, and personnel wearing clothing in different rooms or different cleanliness levels are not allowed to walk around casually. Zhongjing Global Purification can provide consulting, planning, design, construction, installation, transformation and other supporting services for purification plants and clean workshops.

The purpose of buffering is to further supplement human purification measures to prevent pollution from being brought in due to the entry of people, resulting in cross-contamination. The buffering facility can be an airlock room, an air shower room or a buffer room; Personnel and materials in and out of the clean area should have measures to prevent cross-contamination, buffer facilities must be set up between the clean area and the non-clean area, and the flow of people and logistics should be reasonable. An airlock is a small room located at the entrance to a clean room, with a sealed space with two doors, between two or more rooms, such as rooms of different cleanliness levels, for the purpose of airlocking when someone needs to enter or leave these rooms The air flow between the rooms can be controlled; the airlock room is only a room with two doors that can be chained but cannot be opened at the same time. The room that does not send clean air can at most play a buffering role, but it cannot effectively prevent the intrusion of external pollution. , because when people enter the airlock, the outside dirty air has entered the airlock with the entry of people. The buffer room is a measure to prevent contamination when entering the door. It is located between two clean rooms. The buffer room can have several doors, but only one door can be opened at the same time. After this door is closed, other doors are allowed to open. Door; the buffer room must also send clean air to make its cleanliness reach the level of the purification plant to be entered.

For business owners unsure of how to effectively incorporate new technology into our CUSTOM SOLUTION SERVICES, life may have just become a little easier.

Super quality are in offer at PHARMA MACHINERY, welcome to visit us.

There are different types of , mainly extraction machine and extraction machine.

extraction machine CUSTOM SOLUTION SERVICES offer a wide range of extraction machine and gave the user the choice of extraction machine, extraction machine and extraction machine.

GET IN TOUCH WITH Us
recommended articles
Project
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect