Purified Water System Troubleshooting - Industrial Dust Removal Equipment

Purified water system faults and troubleshooting symptoms Troubleshooting methods The original water tank and softened water tank are full of overflowing water The floating ball valve in the water tank is damaged Replace or repair the floating ball valve , The booster pump power is not turned on 1. Turn on the internal power supply and the first-level high-pressure pump does not work1. The booster pump is not turned on 2. The inlet pressure of the high-pressure pump is low 1. Turn on the booster pump 2. The security filter is blocked 3. Clean the security filter element The secondary high-pressure pump does not work 1. The liquid level of the intermediate water tank is low, and the first-stage water flow is adjusted to adjust the balance. The UV sterilizer does not light up. 1. The ultraviolet lamp is broken. 1. The liquid level of the purified water tank is low 1. Increase the water level of the water tank. The flow rate of the pump is insufficient. 1. The inlet and outlet valves of the pump are not opened or the inlet and outlet pipes are blocked. 2. The pump outlet valve or check valve is damaged. , remove the blockage of the pipeline 2, replace or repair the valve 3, check the water level in the water tank, remove the liquid level control failure, the pump does not work, the solenoid valve does not work Power 2. Press the reset button of the thermal relay 3. Turn on the contact power. Thermal relay action 1. The pump is stuck by the sundries 2. The wires are loose and the phase is missing 3. The motor is broken 1. Manually turn the pump motor to remove the sundries 2. Check the wiring and make sure Tighten the connection screw 3. Replace the motor contactor and it does not pull in. 1. The wire head is loose. 2. The control power supply is not turned on. 1. Check the wiring and tighten the connecting wire screw. Valve over-torque action 3, thermal relay action 4, contactor does not pull in 1, turn on the power 2, manually open the valve to the middle position and try again 3, press the thermal relay reset button 4, turn on the power of the contactor.

GET IN TOUCH WITH Us
recommended articles
Project
no data
Contact Us
Telephone: +86-18241958031/
+86-18913598640
Fax: 86-512-65488640
Whatsapp/Wechat: 008618241958031

Notice:
We hereby declare that our company's only legal contact is through the the above email, Any other similar suffix is a scammer email. 
Address: NO.188 xiangwei road, near junction of xiangwei road and chengyang road (the second floor of south building inside of haiji feiyue) Xiangcheng district, Suzhou city, Jiangsu province, China
no data
Copyright © 2025 Suzhou Pharma Machinery Co., Ltd. | Privacy Policy  Sitemap
Contact us
email
whatsapp
contact customer service
Contact us
email
whatsapp
cancel
Customer service
detect